DECANTATION OF FIXED CULTURE BIOLOGICAL SLUDGE

In 2017, SUEZ Industry was looking for a compact solution for the settling of an effluent from a fixed culture biological treatment at the GEMEY lipstick manufacturing plant. The sludge from such a treatment is known to be sticky and incompatible with lamellar settling tank. ExoCell proposed its lamellar settling tank, the ClariDull, equipped as standard with an air washing system allowing a preventive de-clogging.

Installed equipment:

  • Lamellar settling tank ClariDull S,
  • Static mixer for coagulants.

Installation performance

Parameters Input Output
Flow m3/h 10
SS treated waterproof mg/L 80 10

Installation performance

Parameters Input Output
Flow m3/h 10
SS treated waterproof mg/L 80 10